The individual wave brake systems can optionally be equipped with split brake discs and also maintain full functionality even after flooding with up to five meters of water column (higher values available on request). The systems are designed for a flooding duration of up to 72 hours and continue to operate reliably afterward. They can withstand shock loads of up to 150g. The calculated proof of shock resistance and complete ILS documentation will be provided by ATEK Drive Solutions GmbH for you.
Locking the shaft during maintenance and service work
Preventing flow-induced co-rotation during non-operation
Locking device
Locking pin diameter: up to 200 mm Locking moment: up to 3,500 kNm other sizes available on request
Control System and Power Unit
Control Control System
The entire control system of the brake system is taken over by a freely configurable control. This is among other things: flood-proof ATEX-compliant CSA-/UL-compliant with analog or digital execution
Aggregate Power Unit
Electrified/electro-hydraulic low maintenance powerful Noise level: < 62 dB (A) possible
With our CAD configurator, you can precisely adapt our products to your individual requirements and seamlessly integrate them into your development processes. Save valuable time in construction by generating technical data sheets and CAD models at the push of a button. Once your configuration is ready, you can download your finished model with just one click or directly request a customized quote for your project.