Induction motor explained: operating principle, design, types on the 230 V mains, advantages and disadvantages, starting current and selection criteria for your application.

AI This article was created with the help of AI.

How does an induction motor work?

An induction motor is an asynchronous motor. The stator winding generates a rotating field in the air gap, which induces voltages in the rotor. The rotor currents that then flow form, together with the rotating field, a torque that pulls the rotor along. Because the rotor receives energy only through induction, the asynchronous motor is also called an induction motor[1]. If the rotor turns exactly as fast as the rotating field, induced voltage, rotor current and torque disappear. In motor operation, the rotor therefore lags behind; this difference is called slip[1].

The speed of the rotating field, the synchronous speed, follows from n = 60 · f / p with the mains frequency f in Hz and the number of pole pairs p. At 50 Hz, this is 3,000 min-1 with two poles and 1,500 min-1 with four poles. In motor operation, the rotor speed is usually 1 to 8% below the synchronous speed[2], for motors up to about 10 kW rather 3 to 10%[1]. For a four-pole motor with a rated speed of 1,480 min-1, that is (1,500 − 1,480) / 1,500 = around 1.3%. How slip is calculated is shown in our article Slip in the asynchronous motor.

In the synchronous motor, by contrast, the rotor turns exactly with the rotating field. It needs its own excitation field from a DC winding or from permanent magnets and a starting aid: on the mains, for example, a damper cage, otherwise a converter for frequency starting. The asynchronous motor manages without separate excitation[3].

Design of stator and rotor

Stator and rotor cores are made of laminations because both are permeated by alternating fields. Two rotor designs are distinguished[1]:

  • Squirrel-cage rotor (short-circuit rotor): axial bars of copper or aluminium, connected at the end faces by short-circuit rings. In series production, they are mostly cast from aluminium[2]. This design is simple, low-maintenance and robust against faults and is therefore the most widespread electric motor.
  • Slip-ring rotor: three-phase rotor winding, brought out via slip rings and brushes. Additional resistors in the rotor circuit improve the starting behaviour[1].

Single-phase capacitor and shaded-pole motors have a squirrel-cage rotor[5]; the difference from the three-phase motor lies in the stator, which additionally carries an auxiliary winding or a short-circuit ring (see below).

Three-phase or single-phase AC: induction motor on the 230 V mains

On the three-phase mains, three currents offset by 120° in the three winding phases generate the rotating field; the motor starts by itself[2]. You will find more on the three-phase motor in the article Three-phase motors. When a 230 V induction motor is mentioned, by contrast, a single-phase motor on the AC mains is usually meant.

A single-phase alternating field can be decomposed into two counter-rotating rotating fields whose torques cancel each other at standstill. The motor therefore has no starting torque. Once the rotor has been given a push in one direction, the torque in that direction predominates, and it accelerates to close to the synchronous speed[4]. In practice, an auxiliary phase generates the missing rotating field. In addition, about one third of the stator slots remains unused: a single-phase asynchronous motor therefore delivers only about 50% of the power of a three-phase motor of the same size[4].

Types for 230 V operation

The types differ in how the auxiliary phase is created:

TypePrinciplePropertiesTypical uses
Capacitor motorMain winding on the mains, auxiliary winding in series with a capacitor; an elliptical rotating field results[4]Higher mass and lower starting torque than a three-phase motor, additional capacitor required; a starting capacitor increases the starting torque and is switched off after run-up[4]Refrigeration machines, roller shutter drives, grinding machines, small machine tools, fans, heating circulation pumps[5]
Auxiliary phase with starting relay or PTCAuxiliary winding with capacitor or short-circuit winding; after run-up, a current relay or a PTC resistor switches it off[4]Auxiliary winding only for startingCompressors in household refrigeration appliances[4]
Shaded-pole motorA short-circuit ring with usually 1 to 3 turns on part of each pole delays the field there[6]For small power ratings, low efficiency, direction of rotation fixed by the pole arrangement[6]Fans and blowers, drain pumps of older household appliances[6]
Three-phase motor in Steinmetz connectionA capacitor acts as a phase shifter in place of the missing third phase[7]Only for small motors, unsuitable for heavy-duty starting[7]Three-phase motor on single-phase 230 V when no three-phase mains is available

We cover the single-phase motor as a type and the Steinmetz connection in the article Single-phase motor. How the capacitor motor is connected, how you recognize main and auxiliary winding and which faults are typical is described in the article 230V motor with capacitor.

Advantages and limits

What speaks for the induction motor above all is the simple design and the low maintenance. The squirrel-cage rotor has no brushes that wear out. For a short time, the motor can be overloaded with more than twice the rated torque, depending on cooling and duration[2]. The limits are just as clear:

  • Speed: It is not rigid but depends on the slip and thus on the load. It can only be adjusted via pole changing or a frequency converter[2].
  • Starting current: For three-phase motors, it can reach about ten times the rated current; if it is not known, eight times is assumed[2]. For the capacitor motor, it can likewise amount to a multiple of the operating current[5]. Supply line and protection must be designed for it.
  • Holding torque: At standstill, an induction motor has no holding torque[2].
  • Starting torque on the 230 V mains: Single-phase motors start more weakly than three-phase motors[5] and are less suitable for heavy-duty starting.

Selecting an induction motor for 230 V

When selecting, check these points:

  • Power and load: For a single-phase motor, allow for the lower power per frame size. For heavy-duty starting, single-phase motors are less suitable because of the lower starting torque[5]; in Steinmetz connection, a motor is expressly unsuitable for it[7]. A three-phase motor is then better.
  • Speed: It follows the number of poles, at 50 Hz thus close to 3,000 min-1 (two-pole) or 1,500 min-1 (four-pole)[2]. For low output speeds, a gearbox is added; see also our article on the 230V gear motor.
  • Degree of protection: The IP code according to DIN EN 60529 describes the protection of the enclosure. IP54 protects against dust in harmful quantities and against splashing water from all directions, IP55 against water jets from any angle[8].
  • Direction of rotation: A single-phase asynchronous motor must be stopped for reversal and restarted in the other direction[4]. Capacitor motors with two identical windings can be reversed via a changeover switch[5].
  • Mounting type: Foot-mounted or flange motor, mounting of a gearbox or brake.

For efficiency, the Ecodesign Regulation (EU) 2019/1781 applies. According to the information from CEMEP and CAPIEL provided by ZVEI, three-phase motors from 0.75 to 1,000 kW have had to meet at least IE3 since 1 July 2021, and three-phase motors from 0.12 to below 0.75 kW at least IE2. Single-phase asynchronous motors from 0.12 kW are added from 1 July 2023 and must reach at least IE2, regardless of the type of capacitors. Exceptions apply to individual motor types[9].

If you want to control the speed of a capacitor motor, keep in mind: the capacitor generates the auxiliary phase required for starting only at rated frequency. Suitable converters therefore first run the motor up at rated frequency and lower the frequency afterwards; a higher starting torque cannot be achieved this way[10]. Especially at higher power, capacitor motors are increasingly being replaced by three-phase motors fed from the single-phase mains by a frequency converter[5]. The possibilities and limits are covered in our article 230V motor with speed control.

IE3 is the standard efficiency class in Europe for three-phase motors from 0.75 kW; we source IEC standard motors in every efficiency class, and our own motors are not IEC standard motors. As a supplier for the complete drive train, we at ATEK Drive Solutions offer motor, gearbox and brake from a single source. You will find an overview of our product range under motors; for your specific application, we will be happy to advise you personally via our contact page.

Frequently asked questions

Is an induction motor the same as an asynchronous motor?

Yes. Because voltages and currents in the rotor arise only through induction from the rotating field, the asynchronous motor is also called an induction motor. The rotor turns more slowly than the rotating field[1].

What are the advantages of an induction motor?

It is simple in design, low-maintenance and can be overloaded for a short time with more than twice the rated torque[2]. Against this stand the load-dependent speed and the high starting current.

What is the difference between a single-phase and a three-phase induction motor?

The three-phase motor forms its rotating field from three offset currents and starts by itself. The single-phase motor has no starting torque at standstill and needs an auxiliary phase. For the same frame size, it delivers only about half the power[4].

What role does the capacitor play in the single-phase motor?

It shifts the current in the auxiliary winding relative to the main current and thus generates an elliptical rotating field that makes the motor start. An additional starting capacitor increases the starting torque and is switched off after run-up[4].

How high is the starting current of an induction motor?

For three-phase motors, it can be about ten times the rated current[2]. For the capacitor motor, it is likewise a multiple of the operating current[5].

Can I control the speed of a 230 V induction motor with a frequency converter?

In principle, the speed of an induction motor can be adjusted via the frequency[2]. With the single-phase capacitor motor, the capacitor generates the auxiliary phase for starting only at rated frequency; a single-phase converter therefore first runs the motor up at rated frequency and lowers the frequency afterwards[10]. Alternatively, a three-phase motor can be operated on the converter.

What are 230 V induction motors used for?

Typical are heating circulation pumps, fans, refrigeration machines, roller shutter drives and small machine tools[5]. For larger power ratings and heavy-duty starting, three-phase motors are more likely to be used.

How do I choose the right induction motor?

Clarify power, speed, starting torque, direction of rotation, mounting type and degree of protection as well as the required minimum IE class.

Sources

  1. University of Rostock, Institute of Electrical Energy Technology (DE): Teil 3 Asynchronmaschinen (script, part 3 asynchronous machines)
  2. Wikipedia (DE): Drehstrom-Asynchronmaschine (three-phase asynchronous machine)
  3. Wikipedia (DE): Synchronmaschine (synchronous machine)
  4. Wikipedia (DE): Wechselstrommotor (AC motor)
  5. Wikipedia (DE): Kondensatormotor (capacitor motor)
  6. Wikipedia (DE): Spaltpolmotor (shaded-pole motor)
  7. Wikipedia (DE): Steinmetzschaltung (Steinmetz connection)
  8. Wikipedia (DE): Schutzart (IP-Code) (degree of protection, IP code)
  9. ZVEI (DE): Information von CAPIEL und CEMEP zur Ökodesign-Verordnung (EU) 2019/1781 (information from CAPIEL and CEMEP on the Ecodesign Regulation (EU) 2019/1781, 2nd edition, 10 May 2021)
  10. Wikipedia (DE): Frequenzumrichter (frequency converter)