IP69K, IP69, IP67 and IP65 for gearboxes: test parameters according to the standards, differences, the role of seals and what the protection class does not cover.

AI This article was created with the help of AI.

IP69K and IP69: what the protection class means for gearboxes

IP69K gearboxes are used where machines are cleaned with hot water under high pressure. According to IEC 60529, the protection class IP69 describes the test with high-pressure hot water jets[1]; IP69K is the common short form of IP6K9K from the road vehicle standard ISO 20653[2]. The difference between IP67 and IP69K lies in the test: IP67 tests temporary immersion, IP69K a hot water jet[1][6].

An IP rating consists of the letters IP and two digits. The first stands for foreign bodies and dust, the second for water; the 6 means dust-tight[4], the 9 protection against high-pressure and steam-jet cleaning[2]. How the digits are read in detail is explained in the article on the IP code digits according to DIN EN 60529.

The code has two origins. IP69K arose with DIN 40050-9 (1993 edition) for road vehicles; according to Castle Compliance, this standard is considered withdrawn, and ISO 20653 continues the code[5]; the third edition appeared in August 2023[3]. IPX9 entered IEC 60529 with Amendment 2 (2013)[1]. DIN EN 60529 does not define IPX9K[2]. The K denotes special requirements for road vehicles that IEC 60529 does not cover[3]; no source gives a definitive answer on what the letter stands for; Castle Compliance suspects “Kraftfahrzeug” (motor vehicle) or “Kennziffer” (code number)[5].

IP65 and IP67: water jets and temporary immersion

Both classes require dust-tightness and differ in the water test. IP65 suits equipment that may be hit by a water jet from a nozzle, for example outdoors. IP67 designates equipment that may be temporarily immersed.

FeatureIP65 (IPX5)IP67 (IPX7)
Dust (digit 6)Dust-tight; talcum test with a vacuum of at most 2 kPa, up to 8 hours[1]As IP65
Water testWater jet: nozzle 6.3 mm, 12.5 l/min (±5%), 2.5 to 3 m distance, 1 min per m², at least 3 min[1]Temporary immersion for 30 min; below 850 mm height, the lowest point is 1 m below the surface, from 850 mm height the highest point is 150 mm below it[1]
Test mediumFresh water[1]Fresh water[1]

IP66 is the stronger jet test (nozzle 12.5 mm, 100 l/min) and includes the lower water protection degrees; this applies up to and including digit 6, not from 7 onwards[1]. An IP67 device has passed the immersion test, but not necessarily the IPX5 jet test[1][4]. First clarify, therefore, whether water jets, a hot water jet or immersion is the actual load, and specify the matching digit.

Testing: IP69 and IP69K compared

The table shows the parameters separately for both codes. The IEC values supported by [1] follow the standard text, the other values follow the sources; the standard text in the edition required remains authoritative.

ParameterIP69 (IPX9, IEC 60529)IP69K (IP6K9K, ISO 20653)
Water temperature80 ± 5 °C[1]80 ± 5 °C[5]
Water pressureNot specified as a pressure; the IEC defines nozzle and flow rate and tests the jet force[1]80 to 100 bar (8 to 10 MPa)[5]
Flow rate15 ± 1 l/min[1]14 to 16 l/min[5]
Nozzle distanceSmall test specimens 100 to 150 mm[5]; large test specimens 175 ± 25 mm[1]100 to 150 mm[5]
Angle and durationSmall test specimens (largest dimension under 250 mm): 0°, 30°, 60°, 90°, 30 s each. Large test specimens (250 mm and above): spraying from all practically accessible directions, 1 min per m², at least 3 min[1]0°, 30°, 60°, 90°, 30 s each, 2 min in total[5][6]
TurntableSmall test specimens only: 5 ± 1 rpm[1]5 ± 1 rpm[5]
Checking the jetImpact force of the jet is measured on an impact plate[1]; Castle Compliance gives 0.9 to 1.2 N[5]In DIN via pump pressure and nozzle geometry[5]; ISO 2023 describes the measuring method for the impact force[3]
Dust of the first digitIP6X: talcum, non-abrasive[1][5]IP6K: abrasive test dust (Arizona Road Dust)[3][5]

According to Castle Compliance, the water values of the predecessor standard DIN 40050-9 and of the IEC agree in essence[5], Wikipedia gives the water test as identical[4], and a test laboratory sees the difference only in the calibration[6]. The current ISO 20653, by contrast, has extended the test conditions for IPX9K, described the measuring method for the impact force and added tolerances[3]; the freely accessible preview does not give the new values, and the IP69K column applies with this reservation. IP69 and IP69K are therefore not equivalent without checking the edition: in data sheets and tenders, state the standard, the edition and the code according to which testing was done.

IP67 or IP69K: why the higher digit does not include everything

The two tests stress a device differently. IP69 and IP69K prove that it withstands a hot high-pressure jet; immersion is not automatically passed with it. According to the IEC, a device with the 9 alone does not have to meet the requirements of digits 5, 6, 7 and 8 unless it is marked with multiple codes[1]; ISO 20653 says the same for 7, 8 and 9K in relation to the lower degrees up to 6K[3]. A test laboratory accordingly writes that a passed IPX9 or IPX9K does not cover IPX7 or IPX8; the immersion test is additional[6].

This also applies to the water-jet degrees: anyone who tests only the 9 has not demonstrated IPX5 and IPX6. If more is required, several classes are stated, for example IPX5/IPX9 or IPX6/IPX9 according to IEC, IPX6K/IPX9K according to ISO[1][3]. Rule of thumb: where cleaning is done hot and under pressure, IP69 or IP69K is called for; where flooding can occur, IP67 or IP68. For IP68 (continuous immersion), manufacturer and user agree the conditions; they are stricter than for IP67[1].

Seals and testing: what a gearbox needs for IP69K

The finished product is tested with water at 80 °C[6]. According to IEC 60529 (IP69), small devices stand on a turntable, larger ones are sprayed from all practically accessible directions[1]; afterwards the product must meet the acceptance criteria of the product standard[6]. Rubber and plastic parts often melt or deform in the process; material selection and dimensional stability under load of housing, seals and exposed components are decisive[6].

On a gearbox, the output shaft exits the housing. A radial shaft seal seals there; the sealing lip rests on the rotating shaft under spring force. The installation direction is decisive: if the open side faces the pressure side, the pressure presses the lip on; installed the wrong way round, the sealing effect is lost. Axial seals take on subordinate tasks such as dust and splash protection, often as a second seal in heavy contamination[7]. How shaft sealing, pressure compensation and materials interact in gearboxes under high water pressure is described in our article on underwater gearboxes: sealing and pressure compensation.

A design description does not replace a test. Ask for the test report or the manufacturer’s declaration with standard, edition and tested version of the gearbox or geared motor. This applies equally to servo motors and devices with integrated control: the rating refers to the tested product in its tested version.

What the protection class does not cover

IEC 60529 classifies the degrees of protection of enclosures; the tests are run with fresh water[1]. The rating does not guarantee protection against other liquids such as cleaning agents; that requires separate resistance tests[4]. The same applies to corrosion and impact resistance (IK code), which the IP55 article linked above covers.

The protection class does not prove cleanability either. How a gearbox is built to a hygienic design, including surfaces and materials, is explained in hygienic design gearboxes: requirements. The lubricant is equally independent: IP69K says nothing about an NSF H1 fill, and an H1 lubricant does not make a gearbox IP69K-proof. The categories and the changeover are explained in the article on NSF H1 lubricants.

As a supplier of the complete drive train, we at ATEK Drive Solutions design gearbox, motor and brake to match, from a single source. According to ATEK’s own information, our hygienic design gearboxes have smooth, easy-to-clean surfaces; the product page does not state a protection class. You will find an overview of our hygienic design gearboxes in our product range; which protection class and which proof your application requires, we are happy to discuss personally via our contact page.

Frequently asked questions

What does IP69 mean for a gearbox?

The digit 6 stands for dust-tight, the 9 for protection against high-pressure hot water jets. Testing is done with water at 80 ± 5 °C from a flat-jet nozzle at 15 ± 1 l/min; small devices stand on a turntable, large ones are sprayed from all directions[1]. IP69 is the code of IEC 60529[2].

What is the difference between IP69 and IP69K?

IP69 is specified in IEC 60529, IP69K (written IP6K9K) in the road vehicle standard ISO 20653[2]. Both test with water at 80 °C; Castle Compliance gives the water values as essentially the same, but the test dust and the nozzle distance for large equipment as different[5]. The 2023 ISO edition has extended the test conditions for IPX9K[3]. DIN EN 60529 does not define IPX9K[2].

What is the difference between IP67 and IP69K?

IP67 tests temporary immersion for 30 minutes[1], IP69K a high-pressure and steam jet[3]. They are different loads; the tables above compare the parameters.

Is an IP69K gearbox automatically IP67 as well?

No. Anyone who passes IPX9 or IPX9K does not automatically meet IPX7 or IPX8; immersion must be tested additionally[6]. This also applies to the water-jet degrees: anyone who tests only the 9 has not demonstrated IPX5 and IPX6. If more is required, several classes are stated, for example IPX6/IPX9 according to IEC or IPX6K/IPX9K according to ISO[1][3].

What do IP65 and IP67 mean?

Both mean dust-tight (digit 6)[4]. IP65 protects against water jets from a 6.3 mm nozzle at 12.5 l/min, IP67 against temporary immersion for 30 minutes[1].

Are IP69K gearboxes suitable for NSF H1 lubricants?

Protection class and lubricant category are independent of each other. The IP rating describes the test of the enclosure with fresh water[1]; whether a gearbox is filled with an H1 lubricant or approved for it is stated in the manufacturer’s data sheet.

What role do seals and materials play in IP69K?

In the test, water at 80 °C and high pressure stress mainly rubber and plastic parts; material selection and dimensional stability of housing, seals and exposed components are decisive[6]. On the gearbox, a radial shaft seal seals at the exiting shaft[7]. Which materials suit the cleaning agent does not follow from the protection class[4].

What does IP69K offer in food and pharma plants?

The test simulates high-pressure and steam-jet cleaning[3]. It proves that the tested device withstood this load. It does not prove hygienic design or cleanability.

Sources

  1. IEC 60529:1989+AMD1:1999+AMD2:2013, Degrees of protection provided by enclosures (IP Code), text version
  2. Wikipedia (DE): Schutzart
  3. ISO 20653:2023, Road vehicles – Degrees of protection (IP code), preview with foreword, introduction and clause 6
  4. Wikipedia (EN): IP code
  5. Castle Compliance: History of IP69K Nomenclature
  6. CertifiGroup: Weekly Whitepaper #75, Understanding IPX9 & IPX9K Testing (2018)
  7. Wikipedia (DE): Radialwellendichtring