Designing an emergency stop brake: emergency stop and emergency switching off, stop categories 0, 1 and 2, braking time, braking energy, applications and testing at a glance.

AI This article was created with the help of AI.

What is an emergency stop brake?

An emergency stop brake quickly brings moving masses to a standstill when someone actuates the emergency stop or the power fails. This task is usually performed by a safety brake that serves as a holding brake in normal operation: today, safety brakes are mostly used as holding brakes, and holding brakes generally also have to be designed for emergency braking. The braking torque is generated by preloaded springs; without energy, the brake is closed[1]. How safety, holding and service brakes fundamentally differ is shown in our overview of the safety brake.

The distinction between emergency stop and emergency switching off is important. The emergency stop is intended to eliminate hazards from hazardous movements as quickly as possible. Emergency switching off relates to risks from electrical voltage and disconnects the machine or parts of it from the supply without delay; it requires that an immediate interruption of the energy supply is permissible[2].

The legal basis is the Machinery Directive 2006/42/EC: every machine must be equipped with one or more emergency stop devices that bring the hazardous process to a standstill as quickly as possible without creating additional risks. Exceptions include hand-held and hand-guided machines[2]. From 20 January 2027, the Machinery Regulation (EU) 2023/1230 replaces the directive[3].

Stop categories 0, 1 and 2

How a machine is stopped is described by the stop categories. According to DIN EN ISO 13850 and DIN EN 60204-1, the emergency stop must be implemented in stop category 0 or 1; which of these is determined by the risk assessment[2]. Stop category 2 is only mentioned in EN 60204-1; it maintains the energy even at standstill[4].

Stop categorySequenceRole of the brake
0immediate interruption of the energy supply to the drives or mechanical disconnection, if necessary with braking devicesThe brake engages immediately and absorbs the kinetic energy.
1controlled stop with energy at the drive, disconnection of the energy after standstillThe drive decelerates; the brake then holds the standstill.
2safe state, the energy is not disconnected (example: crane with lifting magnet)not permissible for the emergency stop

For the emergency stop function, DIN EN ISO 13850 requires at least performance level c according to DIN EN ISO 13849-1, i.e. at least category 1 with a single-channel structure and well-tried components[2]. For vertical axes, the DGUV recommends preferring stop category 1 to stopping with mechanical brakes, both for operational stopping and in an emergency, if the risk assessment permits it; this avoids unnecessary wear of the holding brakes[5].

Calculating braking time and braking distance

The required braking torque is made up of the deceleration torque and the load torque[6]:

  • MBr = Ma ± ML (ML: load torque, braking or driving)
  • Ma = J · n / (9.55 · ta) with J in kgm², n in rpm and ta in s
  • MN = 9550 · PN / n with PN in kW

Rearranged, this gives the braking time t = J · n / (9.55 · (MBr ∓ ML)). A driving load torque, such as a descending load, extends it. An example with the values of a 7.5 kW motor (1,500 rpm, rotor moment of inertia J = 0.029 kgm², without external masses) and a 50 Nm brake[6]: without load torque, t = 0.029 · 1500 / (9.55 · 50) ≈ 0.09 s. With uniform deceleration, the rotor continues to turn around 1.1 revolutions in this time. Added to this are the reaction time of the control system and the switching time of the brake, which becomes longer as lining wear increases[1].

As a rule of thumb, a braking torque of at least 80 % of the rated torque applies for run-down braking, and twice the rated torque in hoisting operation; when lowering, about half of this is consumed statically. Deviations should remain within a factor of 0.5 to 2.5: a brake that is too small wears faster, while one that is too large puts excessive stress on the mechanical transmission elements. Guide values for the overtravel time are about 50 ms to 1 s for run-down braking and 120 to 800 ms for lowering in hoisting operation, based on 4-pole three-phase motors from 1 to 100 kW. On the driven machine, the reduction gear usually connected downstream shortens the overtravel distance[6].

Braking energy during an emergency stop

In addition to torque, heat limits emergency braking. The kinetic energy is converted into heat by friction, and the load must not exceed the energy capacity of the brake. The rotational energy is W = J · n² / 182.5 (W in J, J in kgm², n in rpm). For a 4-pole 11 kW motor with J = 0.057 kgm² at 1,500 rpm, this amounts to around 703 J, as much as is needed to lift about 72 kg by one metre[7].

For a single braking operation, the thermal recalculation can be dispensed with in the usual applications. The limit can be reached if a mechanical deceleration designed only as emergency braking takes place several times in succession from maximum speed. With very large mass moments of inertia from high speed, heat build-up at the friction surface is a risk, and in lowering operation with static load torque, the thermal stress increases. Because the stress decreases with the square of the speed, every braking operation from a lower speed spares the brake considerably[7].

In addition, a passed static brake test says little about the emergency stop properties: a brake acts differently dynamically than statically, so that a slightly longer overtravel distance is possible despite a passed test. Whether this represents an unacceptable risk must be clarified by the machine manufacturer’s risk assessment[5]. For vertical axes, the IFA therefore recommends a dynamic brake test in addition to the static test: at regular intervals, at most annually, the brake engages under defined conditions for speed and mass; overtravel distance and overtravel time are compared with the permissible values, and if a value is exceeded, further operation must be prevented[8].

Applications for emergency stop brakes

  • Hoists and cranes: the load acts as a driving load, so the rule of thumb is twice the rated torque; hoist brakes are larger and brake harder than brakes for pure run-down operation[6].
  • Vertical axes: on linear robots, articulated robots and vertical axes of machining and turning centres, the motor brake often takes on emergency stop tasks in addition to holding the axis up[5]. More on this in the article Safety brakes for vertical axes.
  • Wind turbines: all turbines must have two mutually independent braking systems. With stall control, the brake must be able to absorb the entire kinetic energy of rotor and generator in an emergency[9].
  • Elevators: separate standards and tests apply here; we describe them in the article Safety brakes for elevators.

Testing, maintenance and selection

Emergency stop equipment should be subjected to a visual and functional test by a competent person at least once a year; depending on the application, shorter intervals may be necessary[2]. On the brake, wear is decisive: the friction work gradually increases the working air gap. Above a limit air gap, for example in the order of 1 to 2 mm, the magnetic force is no longer sufficient for reliable release; the initial air gap, for example around 0.25 mm, must then be restored or the brake disc replaced[7]. The type, scope and intervals of recurring tests for dangerous wear are determined by the operator[5].

These questions lead to the right emergency stop brake:

  • Which stop category results from the risk assessment, and does the brake only brake in the event of a power failure or at every emergency stop?
  • Which braking torque follows from mass moment of inertia, speed, load torque and permissible overtravel time?
  • How large is the braking energy per emergency stop, and how many emergency stops can occur in succession?
  • With which energy is the brake released: electromagnetically, hydraulically or pneumatically[1]?
  • Which ambient conditions apply? Degree of protection IP65, for example, stands for dust-tight and protected against water jets[10]; the temperature range must also be considered.

Motor, gearbox and brake must match in terms of torque, speed and control. As a supplier for the complete drive train, we at ATEK Drive Solutions design motor, gearbox and brake to fit precisely from a single source. In our range of brakes you will find spring-applied lever, fixed caliper and floating caliper brakes, which, depending on the version, are released hydraulically, pneumatically or electrically. We will be happy to advise you personally on your application; please contact us.

Frequently asked questions

What is the difference between emergency stop and emergency switching off?

The emergency stop stops hazardous movements. Emergency switching off disconnects the energy without delay in the event of hazards from electrical voltage and requires that stop category 0 is permissible.

Which stop category applies to the emergency stop?

Stop category 0 or 1. In category 0, the energy is disconnected immediately and the brake engages; in category 1, the drive decelerates and the energy is only disconnected at standstill.

Can a holding brake serve as an emergency stop brake?

Yes, if it is designed for this; this is generally required for holding brakes. However, a static brake test does not fully show whether the emergency stop properties are deteriorating; for vertical axes, the IFA therefore additionally recommends a dynamic brake test at least once a year.

How do I calculate the braking time of an emergency stop brake?

With t = J · n / (9.55 · (MBr ∓ ML)), J in kgm², n in rpm and torques in Nm. A driving load torque is subtracted from the braking torque. The reaction time of the control system and the switching time of the brake are added to the pure braking time.

Which performance level is required for the emergency stop function?

DIN EN ISO 13850 requires at least PL c according to DIN EN ISO 13849-1; product standards (type C standards) can specify further requirements. For new machines for which no type C standard provides information, the BG RCI recommends PLr d with category 3 if protective devices that fully safeguard the risk cannot be applied according to the state of the art and irreversible injuries are possible.

How often must emergency stop equipment be tested?

The interval is determined by the operator in the hazard assessment. The BG RCI recommends a visual and functional test by a competent person at least once a year; before each use, a check for obvious defects is required. For the brake, air gap and lining wear are part of the test.

Which degree of protection does an emergency stop brake need in harsh environments?

IP65 means dust-tight and protected against water jets, IP66 dust-tight and protected against powerful water jets. The permissible temperature range must also be considered.

What does the Machinery Directive require of the emergency stop?

The device must be clearly visible and quickly accessible and stop the hazardous process as quickly as possible. After actuation, the stop command remains latched until the device is deliberately reset; the reset must not restart the machine. The emergency stop must be available in every operating mode and supplements other protective measures but does not replace them. From 20 January 2027, the Machinery Regulation (EU) 2023/1230 takes the place of the directive.

Sources

  1. Wikipedia (DE): Sicherheitsbremse (safety brake)
  2. BG RCI (DE): Emergency stop and emergency switching off equipment (as of 28 January 2024)
  3. Wikipedia (DE): Verordnung (EU) 2023/1230 (Machinery Regulation)
  4. Wikipedia (DE): Nothaltschalter (emergency stop)
  5. DGUV Fachbereich AKTUELL FBHM-005 (DE): Gravity-loaded axes – vertical axes (as of 17 August 2021)
  6. elektropraktiker.de (DE): Spring-applied brakes on electric motors, part 1 – selection by braking torque
  7. elektropraktiker.de (DE): Spring-applied brakes on electric motors, part 2 – selection by braking energy
  8. IFA Report 4/2018 (DE): Safe drive controls with frequency converters (3rd edition)
  9. Wikipedia (DE): Windkraftanlage (wind turbine)
  10. Wikipedia (DE): Schutzart (IP code)