Capacitor motor calculation: formula, µF per kW, table for 230 V, start and run capacitor, Steinmetz circuit and voltage rating.
AI This article was created with the help of AI.
Table of contents
- Capacitor motor calculation: formula and method
- What the capacitor does in a single-phase AC motor
- Rules of thumb and table for 230 V motors
- Calculating the start capacitor and run capacitor
- Calculating the capacitor for the Steinmetz circuit
- Voltage rating, design and standard
- Detecting incorrect sizing and replacing the capacitor
- Frequently asked questions
- Sources
Capacitor motor calculation: formula and method
In a capacitor motor, the capacitor is connected in series with the auxiliary winding. Its capacitance determines which current flows in this branch and how far it is phase-shifted relative to the current in the main winding. For the calculation, you use the reactance of the capacitor: X_C = U_C / I_C = 1 / (2π · f · C). Solving for the capacitance gives the basic formula:
C = I_C / (2π · f · U_C)
- I_C is the current through the capacitor and the auxiliary winding in amperes. It is not identical to the rated current on the nameplate; it is measured or determined from the winding data.
- f is the mains frequency, 50 Hz in Europe.
- U_C is the voltage at the capacitor. It depends on speed and load and is higher than the mains voltage; for the Steinmetz circuit it is taken as 1.2 times the mains voltage[1]. We use this value as an assumption in the following example.
- C is obtained in farads. Multiplied by 1,000,000, you get the value in µF.
A worked example with assumed values: if I_C = 1.3 A flows in the capacitor branch and U_C = 1.2 · 230 V ≈ 276 V is present at the capacitor, the result is C = 1.3 A / (2π · 50 Hz · 276 V) ≈ 15 µF. This corresponds to the rule-of-thumb value for a 0.75 kW motor in the table below. In practice, the capacitor current is rarely known, so calculations are usually based on rules of thumb. In addition, the capacitance is only ever optimal for one load case of speed and torque[2]. How much current a motor draws in total is shown in our article on the current consumption of three-phase motors.
What the capacitor does in a single-phase AC motor
A single-phase asynchronous motor develops no torque at standstill, because a single winding does not produce a rotating field; it needs its own starting circuit. Larger single-phase motors therefore have a second stator winding that is fed with a phase-shifted current; in the capacitor motor, a capacitor produces this phase shift. This starting circuit also determines the direction of rotation; it is reversed by swapping the connections of the auxiliary winding[3].
The rotating field produced in this way depends on the load and results in a low starting torque. With optimum capacitor sizing, a capacitor motor achieves about 65 % of the mechanical power of a three-phase motor of the same size. It is used for lower power ratings, for example in circulation pumps, roller shutter motors, bench grinders, small machine tools and refrigeration machines[2]. Our article on the single-phase motor gives an overview of the designs, and the guide 230 V motor with capacitor: circuit diagram explains the wiring in the terminal box.
Rules of thumb and table for 230 V motors
For the run capacitor of a capacitor motor, typical capacitance values are about 20 to 25 µF per kW of motor power. If a start capacitor is connected in parallel for heavy starting, the total capacitance during starting can be up to about 60 to 100 µF per kW[2]. For a three-phase motor in a Steinmetz circuit, a guide value of about 70 µF per kW is recommended at 230 V[1].
The following table converts these rules of thumb for common motor power ratings at 230 V and 50 Hz. The values are rounded guide values; the data on the nameplate or the old capacitor remain authoritative.
| Motor power | Run capacitor (20–25 µF/kW) | Run plus start capacitor for heavy starting (60–100 µF/kW) | Steinmetz circuit (approx. 70 µF/kW) |
|---|---|---|---|
| 0.25 kW | 5–6 µF | 15–25 µF | approx. 18 µF |
| 0.37 kW | 7–9 µF | 22–37 µF | approx. 26 µF |
| 0.55 kW | 11–14 µF | 33–55 µF | approx. 39 µF |
| 0.75 kW | 15–19 µF | 45–75 µF | approx. 53 µF |
| 1.1 kW | 22–28 µF | 66–110 µF | approx. 77 µF |
| 1.5 kW | 30–38 µF | 90–150 µF | approx. 105 µF |
A capacitor for a 1 kW motor is therefore around 20 to 25 µF of run capacitance, and around 70 µF in a Steinmetz circuit. The table ends at 1.5 kW: depending on the grid, utilities limit the permission for motors in a Steinmetz circuit to this power, and both the Steinmetz circuit and the capacitor motor are restricted to drives up to about 2 kW for technical and economic reasons[1].
Calculating the start capacitor and run capacitor
The run capacitor remains permanently in series with the auxiliary winding and provides the phase shift during operation. The start capacitor is connected in parallel with the run capacitor only during starting and is about 2 to 3 times as large[2]. After run-up, it must be disconnected via a centrifugal switch or a timing relay[1]. Alternatively, a PTC thermistor disconnects the auxiliary branch: it heats up, increases its resistance and reduces the current to an insignificant value[3].
This gives the calculation method for the start capacitor: first determine the run capacitor C_R and multiply it by 2 to 3. For a 0.75 kW motor with C_R = 15 to 19 µF, the start capacitor is therefore about 30 to 57 µF. Together with the run capacitor, this gives 45 to 76 µF during starting, i.e. roughly the range of 60 to 100 µF per kW (45 to 75 µF).
| Feature | Run capacitor | Start capacitor |
|---|---|---|
| Connection | permanently in series with the auxiliary winding | in parallel with the run capacitor during starting |
| Function | phase shift and torque during operation | higher starting torque, for example for heavy starting |
| Capacitance | approx. 20–25 µF per kW | approx. 2 to 3 times the run capacitor |
| Disconnection | none | after run-up via centrifugal switch, timing relay or PTC thermistor |
The two components are not interchangeable. If the start capacitor remains connected after run-up, for example because of a defective switch, the motor winding overheats[1]. In addition, bipolar electrolytic capacitors, which are only permitted for short-time operation, are usually used as start capacitors in the Steinmetz circuit[1]; they are therefore not suitable as run capacitors.
Calculating the capacitor for the Steinmetz circuit
With the Steinmetz circuit, a three-phase motor runs on the single-phase 230 V mains. Depending on the desired direction of rotation, the run capacitor is connected from one of the two supply terminals to the third terminal. In practice, the delta connection is usually used at 230 V, i.e. a motor with 230/400 V on the nameplate[1]. The capacitance can be calculated using this formula[1]:
C = 2 · P / (√3 · ω · U²) with ω = 2π · f
For a 1.1 kW motor at 230 V and 50 Hz, this gives C = 2 · 1,100 W / (1.732 · 314.2 s⁻¹ · 230² V²) ≈ 76 µF. This matches the guide value of about 70 µF per kW, which comes from the now withdrawn DIN 48501[1]. The optimum capacitance cannot be calculated exactly; it is determined empirically on a dynamometer test bench[4].
Expect losses: the power of a three-phase motor in a Steinmetz circuit is about 80 % of the rated power[1], while other sources state a power loss of around 30 %[4]. Depending on the size of the run capacitor, the starting torque is between 20 % and 50 % of the rated torque; with a start capacitor that can be up to twice as large as the run capacitor, it rises to almost 100 %[1].
Voltage rating, design and standard
The capacitor and winding form a series resonant circuit, so during operation the voltage at the capacitor is higher than the mains voltage. This overvoltage depends on speed and load; in the Steinmetz circuit, the capacitor voltage is therefore set at 1.2 times the mains voltage. On the 230 V mains, the capacitor should be rated for 400 to 450 V AC, both in the capacitor motor and in the Steinmetz circuit[1]. The voltage stated on the capacitor therefore describes its withstand capability, not the mains voltage at which it is operated.
- Design: For safety reasons, self-healing MKP capacitors are used[2], and metallized paper capacitors are also used as run capacitors[1].
- Standard: DIN EN 60252-1 (VDE 0560-8) applies to motor capacitors in single-phase systems up to 100 Hz, including for three-phase asynchronous motors on single-phase mains, with rated voltages up to 660 V. It states that operation above the rated voltage reduces the service life and specifies the probable service life via the class of operation[5].
- Temperature: The permissible operating voltage of film capacitors decreases as the temperature rises; if the maximum AC voltage is exceeded, the capacitor can be destroyed[6].
Detecting incorrect sizing and replacing the capacitor
Because the capacitance determines the current in the auxiliary winding, deviations in either direction have an effect. If the capacitor is too small, too little current flows in the auxiliary branch: the starting torque falls, and under load the motor starts with difficulty or not at all. If it is too large, the current in the auxiliary winding rises above the design value and the winding heats up more. A “larger capacitor to be on the safe side” is therefore not a solution, not even for the start capacitor.
Even a correctly selected capacitor changes during operation. In self-healing film capacitors, each self-healing event reduces the capacitance slightly, usually by much less than 1 % of the total capacitance. Ageing becomes apparent mainly at high ambient temperatures or high current loads[6]. A defective capacitor usually shows itself in that the motor hums on the mains but does not start on its own: without the phase-shifted current of the auxiliary winding, a single-phase asynchronous motor develops no torque at standstill[3]. An aged capacitor is first noticed through weak starting under load. If the measured capacitance is significantly below the printed value, the capacitor must be replaced. When replacing it:
- Disconnect the motor from the mains and discharge the capacitor before touching it.
- Choose the same capacitance in µF and the same or a higher voltage rating, never a lower one.
- Do not confuse the run and start capacitor; with the start capacitor, also check the disconnection mechanism.
- After the replacement, compare the current consumption with the rated current on the nameplate.
Where a single-phase drive reaches its limits, for example with high starting torque or power ratings above the permissible limit, a three-phase motor is usually the better basis. On single-phase mains, a frequency converter generates the three phases for it; this is why three-phase motors are increasingly replacing capacitor motors, especially in the upper power range[2]. As a supplier for the complete drive train, we at ATEK Drive Solutions design motor, gearbox and brake to fit precisely from a single source. You will find an overview of our IEC standard motors in our product range, and we will be happy to advise you personally on your specific application via our contact page.
Frequently asked questions
How do I calculate the capacitor for a 230 V motor?
Using the formula C = I_C / (2π · f · U_C). I_C is the current in the capacitor branch, f the mains frequency of 50 Hz and U_C the capacitor voltage, which is higher than the mains voltage; for the Steinmetz circuit, 1.2 times the mains voltage is assumed. The result in farads multiplied by 1,000,000 gives µF. Without measured values, calculate with 20 to 25 µF per kW for the run capacitor.
How many µF does a motor need per kW?
A capacitor motor needs about 20 to 25 µF of run capacitance per kW. For heavy starting with an additional start capacitor, it is up to 60 to 100 µF per kW during starting. A three-phase motor in a Steinmetz circuit needs around 70 µF per kW at 230 V, i.e. about 70 µF for 1 kW.
How do I calculate the start capacitor?
First determine the run capacitor and multiply it by 2 to 3. For a 0.75 kW motor with 15 to 19 µF of run capacitance, this gives a start capacitor of about 30 to 57 µF. In the Steinmetz circuit, the start capacitor can be up to twice as large as the run capacitor.
What is the difference between a start capacitor and a run capacitor?
The run capacitor remains permanently connected to the auxiliary winding and produces the phase shift during operation. The start capacitor is connected in parallel only during starting, increases the starting torque and is disconnected after run-up via a centrifugal switch, timing relay or PTC thermistor.
What voltage rating does the capacitor need on the 230 V mains?
400 to 450 V AC is common. The voltage at the capacitor is higher than the mains voltage because the capacitor and winding form a series resonant circuit; for the Steinmetz circuit, it is taken as 1.2 times the mains voltage. A replacement capacitor may have a higher voltage rating than the original, but never a lower one.
What happens if the capacitor is too large or too small?
A capacitor that is too small supplies too little current in the auxiliary winding; the motor starts with difficulty or not at all under load. A capacitor that is too large increases the current in the auxiliary winding, and the winding heats up more. For this reason, do not replace a capacitor with one of higher capacitance.
Does an AC motor run without a capacitor?
A capacitor motor does not: a single-phase asynchronous motor develops no torque at standstill and needs a starting circuit, which in the capacitor motor is the capacitor. A running motor can continue to run when the starting branch is disconnected, but it does not start on its own.
What do I need to look out for when replacing a capacitor?
Disconnect the motor from the mains and discharge the capacitor. Choose the same capacitance, the same or a higher voltage rating and the same type (run or start capacitor). After the replacement, check the current consumption against the rated current on the nameplate.
Sources
- Wikipedia (DE): Steinmetzschaltung (Steinmetz circuit)
- Wikipedia (DE): Kondensatormotor (capacitor motor)
- Wikipedia (EN): Induction motor
- elektropraxis.at (DE): Welche Kapazität braucht mein Kondensator? (What capacitance does my capacitor need?)
- DKE (DE): DIN EN 60252-1 (VDE 0560-8):2011-10 Motor capacitors
- Wikipedia (DE): Kunststoff-Folienkondensator (plastic film capacitor)