Your Choice: Type VLM 120
Characteristics
Performance Data

Characteristic Standard Option
Toothing Bevel gear, spiral-toothed See chapter 6.2.1
Gear ratio 3:1 to 6:1
Housing / Flanges Grey cast iron
Threaded mounting hole On all housing surfaces without flange and on all flanges. See chapter 6.2.3
Shaft Material 1 C45, shaft ends greased

Fit with ISO 6 tolerance with parallel keyway: according to DIN 6885 Sheet 1

See chapter 4.6.2
Hollow shaft Material 1 C45, shafts greased

Fit with ISO 7 tolerance with parallel keyway: according to DIN 6885 Sheet 1

See chapter 4.6.3
Radial shaft seal ring NBR, form A See chapter 4.8
Ambient temperature - 10°C to +90°C. The values of the performance tables are valid for +20°C See chapter 4.9.3
Circumferential backlash < 30 arcmin See chapter 6.2.10
Protection class IP 54 See chapter 4.5
Corrosion protection Prime coat; layer thickness > 40 µm See chapter 4.4.1
Bearing life L10h more than 15,000h See chapter 4.9.1
Oil change intervals Not required if the oil temperature is kept < 90°C

The lifetime of the bearings can be increased by the factor 1.5 if the oil is changed after the first 500 service hours and then every 5000 service hours.

See chapter 6.2.8
Lubricants Synthetic lubricants See chapter 6.2.8
Motor IEC standard motor in the prescribed efficiency class

P1 [kW] n2  [rpm] T2 [Nm] T2N [Nm] T2MAX [Nm] i [-] IEC motor Gearbox size P1NT [kW]
0.55 272 18.4 72 140 5:1 080A-4 120 6.2
172 28.9 82 155 4:1 090L-8 120 6.2
150 33.3 67 120 6:1 080B-6 120 6.2
138 36.2 86 140 5:1 090L-8 120 6.2
115 43.4 69 120 6:1 090L-8 120 6.2
0.75 606 11.2 86 100 1.5:1 090S-6 120 6.2
303 22.4 82 155 3:1 090S-6 120 6.2
272 25.0 72 140 5:1 080B-4 120 6.2
227 30.0 64 120 6:1 080B-4 120 6.2
182 37.4 80 140 5:1 090S-6 120 6.2
152 44.8 67 113 6:1 090S-6 120 6.2
138 49.3 86 140 5:1 100LA-8 120 6.2
115 59.2 69 118 6:1 00LA-8 120 6.2
1.1 920 10.9 78 100 1.5:1 090S-4 120 6.2
690 14.5 73 80 2:1 090S-4 120 6.2
606 16.5 86 100 1.5:1 090L-6 120 6.2
564 17.7 60 140 5:1 080B-2 120 6.2
460 21.7 74 155 3:1 090S-4 120 6.2
345 28.9 74 155 4:1 090S-4 120 6.2
303 32.9 82 155 3:1 090L-6 120 6.2
276 36.2 72 140 5:1 090S-4 120 6.2
227 43.9 79 155 4:1 090L-6 120 6.2
182 54.8 80 140 5:1 090L-6 120 6.2
152 65.7 67 120 6:1 090L-6 120 6.2
138 72.3 86 140 5:1 100LB-8 120 6.2
15 1420 9.6 56 80 2:1 090S-2 120 6.2
946 14.4 58 155 3:1 090S-2 120 6.2
920 14.8 78 100 1.5:1 090L-4 120 6.2
710 19.2 60 155 4:1 090S-2 120 6.2
690 19.7 73 80 2:1 090L-4 120 6.2
613 22.2 78 100 1.5:1 100LA-6 120 6.2
568 24.0 60 140 5:1 090S-2 120 6.2
460 29.6 74 155 3:1 090L-4 120 6.2
345 39.5 74 155 4:1 090L-4 120 6.2
306 44.4 82 155 3:1 100LA-6 120 6.2
276 49.3 72 140 5:1 090L-4 120 6.2
230 59.2 64 120 6:1 090L-4 120 6.2
184 74.0 80 140 5:1 100LA-6 120 6.2
2.2 1893 10.5 61 100 1.5:1 090L-2 120 6.2
1420 14.1 56 80 2:1 090L-2 120 6.2
940 21.2 78 100 1.5:1 100LA-4 120 6.2
710 28.1 60 155 4:1 090L-2 120 6.2
626 31.9 80 100 1.5:1 112M-6 120 6.2
568 35.1 60 140 5:1 090L-2 120 6.2
470 42.5 74 155 3:1 100LA-4 120 6.2
352 56.6 74 155 4:1 100LA-4 120 6.2
313 63.7 82 155 3:1 112M-6 120 6.2
3 2850 9.6 66 220 1:1 100L-2 120 6.2
1900 14.3 61 100 1.5:1 100L-2 120 6.2
1410 19.3 82 220 1:1 100LB-4 120 6.2
940 29.0 78 100 1.5:1 100LB-4 120 6.2
705 38.6 73 80 2:1 100LB-4 120 6.2
570 47.8 60 140 5:1 100L-2 120 6.2
470 57.9 74 155 3:1 100LB-4 120 6.2
4 2860 12.7 66 220 1:1 112M-2 120 6.2
1906 19.0 61 100 1.5:1 112M-2 120 6.2
1420 25.6 82 220 1:1 112M-4 120 6.2
946 38.3 78 100 1.5:1 112M-4 120 6.2
710 51.1 73 80 2:1 112M-4 120 6.2